Midnite Solar, Pre-wired off-grid system, with Magnum MS4448PAE 120/240 VAC Off-Grid 4,400 Watt 48 VDC Inverter with Classic 150, MNEMS4448PAECL150
MidNite Solar offers pre-assembled and tested power panels using Magnum, SMA, and Schneider inverters. These power panels offer a space-saving fully-integrated power-panel system. All assemblies are thoroughly tested and crating is included.
Magnum inverters are installed on the MidNite MNE250(175)STM-L gray steel E-Panel with an ME-RC50 remote display, a WhizBang Jr, a MidNite Classic 150 charge controller with built in DC-GFP and arc-fault detector, an MNDC array breaker, an MNDC charge- control breaker, two or three MNSPD surge arrestors, and battery-temperature sensors. (See Electrical Distribution Parts for details on these components) Also available with CL200 and CL250 charge controls.
The MidNite MND3R4024PAE-UPS is a battery-based backup system in a battery and equipment enclosure. It is made specifically for AC backup power. It has 120/240 VAC output, and is fully assembled and tested. Includes a Magnum MS4024 PAE inverter, Magnum ARC50, and MidNite Enclosure. It can hold four Group 31 or GC2 or GC2 tall batteries (batteries not included). 49H x 39W x 21D.
The MidNite MNEMS4024PAEACCPL is a Magnum battery-based inverter system, made for AC coupling to a grid-tie inverter. It is available with 120/240 VAC output, and is fully assembled and tested. Includes a Magnum MS4024 PAE inverter, Magnum RTR router, MidNite E-Panel, two SPD surge arrestors, and GT-inverter-circuit relay. The maximum size grid-tie inverter that can be installed with this system is 3.6 kW. 30H x 16W x 12D.
The MidNite MND3RACCPLME is a Magnum battery-based inverter system, made for AC coupling to a grid-tie inverter, in an outdoor enclosure with room for batteries. It has 120/240 VAC output, and is fully assembled and tested. Includes a Magnum MS4024 PAE inverter, Magnum RTR router, MidNite E-Panel, two SPD surge arrestors, and GT-inverter-circuit relay. This is all installed inside a MidNite MNBE-D3R battery enclosure which, in this configuration, can hold four Group 31 or GC2 or GC2 tall batteries (batteries not included). The maximum size grid-tie inverter that can be installed with this system is 3.6 kW. 49H x 39W x 21D. The dimensions and weights are approximate and do not include crating.
Please note that not all grid-tie inverters are suitable for AC coupling; check with the inverter manufacturer.
Features
User Friendly - One rectangular cut-out for mounting a North American GFCI style AC outlet. Inverter, remote control and charge controller mounting hardware included. Dual 50 amp AC input disconnects for generator or utility (prewired). Inverter battery breaker, inverters cables and snap in grommets included. Inverter mounts on a unique hinged door to keep a small system foot-print.
Efficient - Cut-outs for mounting up to six additional 13mm wide din-rail mount AC and DC breakers (for circuits such as PV, wind, hydro or AC distribution). Bracket included for mounting optional charge controller (Classic or MX60). Dual 50 amp inverter AC Bypass Switch (prewired). E-Panel mounting brackets are included to aid in one person installations.
Safety - Conforms to UL508A 1st Edition and CSA C22.2 #14-M95 (Industrial Control Panel). Heavy duty 150 amp bus-bars for AC HOT, NEUTRAL, GROUND, BATT +/- and PV + included. 500 amp/50 mV shunt included for battery monitoring systems. Powder-coated steel chassis with knockouts to accommodate various install needs.